| Model | EGN 9471 |
|---|
| Appliance type | Freezer |
|---|
| Energy efficiency class | Stated as an energy efficiency class rating (exact class not specified here) |
|---|
| Energy consumption | Annual and 24 h energy consumption in kWh specified (exact figures not restated) |
|---|
| Noise output | Noise level in dB(A) and noise class specified |
|---|
| Total volume* | Value in litres given in accordance with Regulation (EU) 2019/2016, rounded to nearest integer |
|---|
| Number of storage shelves | Number stated, including how many are height-adjustable |
|---|
| Number of door racks | Number stated for freezer door |
|---|
| Number of FrostSafe drawers | Stated number of FrostSafe drawers with SoftTelescopic |
|---|
| Electronic control system | InfinitySwipe |
|---|
| Automatic SuperFrost | Yes – automatic, with return to normal operation after max. 65 hours |
|---|
| Freezer temperature range | -14°C to -27°C |
|---|
| Defrosting method | Automatic NoFrost system |
|---|
| Interior lighting | InfinityLight LED, plus InfinityBeam for drawers |
|---|
| IceMaker | Yes, automatic; fixed water connection 3/4' |
|---|
| Water filter | Yes; located in the front section of the appliance plinth and easily accessible |
|---|
| Ice production in 24 h | 1.6 kg (with increased capacity when SuperFrost is activated) |
|---|
| Ice storage capacity | 1.8 kg to 3.5 kg, depending on model |
|---|
| Storage time in event of fault | Stated in hours (exact figure not restated) |
|---|
| Freezing capacity in 24 h | Stated in kg per 24 h |
|---|
| Door hinge | Left, reversible (door hinge reversal by authorised Liebherr customer service) |
|---|
| Appliance dimensions (H/W/D) | 212.6 / 75.4 / 61 cm |
|---|
| Recess dimensions (H/W/D) | 213.4 / 76.2 / 63.5 cm |
|---|
| Net weight | 161.0 kg |
|---|
| Voltage / connected load | 220–240 V~ / 2.0 A |
|---|
| Climate class | SN–T (intended for ambient temperatures from 10°C to 43°C) |
|---|
| Appliance depth | 610 mm appliance depth; designed for installation in 610 mm or 635 mm cut-outs |
|---|
* Total volume indicated to the nearest integer (rounded off) in accordance with Regulation (EU) 2019/2016.
Installation space and recess requirements
The appliance is designed for flush installation in units with a depth of 635 mm using stainless steel or customer-specific panels. It can also be installed in standard European 610 mm deep units. The recess dimensions for the EGN 9471 are 213.4 / 76.2 / 63.5 cm (H/W/D). The floor must be level and capable of bearing the weight of the appliance plus food. Recess dimensions must be measured correctly and the power socket positioned appropriately.
The top and carcass walls must line up flush with the appliance at a depth of at least 102 mm from the outside edge and be at least 16 mm thick. As parts of the recess are visible with the door open, matching finishes from the kitchen manufacturer are recommended. A decorative trim to cover the gap between the appliance and unit side walls is included in the scope of supply.
Door panels and plinth panel
The EGN 9471 supports both inset and overlay door panel installation. For inset installation, appliance height is 2029 mm and width 756 mm. For overlay installation, appliance height is 2032 mm and width 762 mm, plus any panel overlap. Panel thickness must be between 16 mm (minimum) and 30 mm (maximum), with a maximum panel weight of 35 kg for this model. If a five-piece shaker style panel thinner than 16 mm is used, shorter screws than those supplied must be used.
The Monolith plinth panel height is a minimum of 102 mm. The adjustable feet are fully retracted at the minimum height. Raising the adjustable feet from the front until the appliance contacts the anti-tipping device increases height; for the 102 mm plinth height, feet must be raised by 6 to 8 mm. A stainless steel plinth panel 76.2 cm wide (102 mm high) is available as an optional accessory for the EGN 9471. The plinth must not obstruct ventilation grilles and must be positioned so that the door panels close at least 102 mm above the floor.
Door spacing and installation options
Monolith appliances are ventilated entirely via the plinth panel and must be installed so that doors and handles do not collide with adjoining walls or kitchen elements. A minimum spacing of 76 mm is required for a door opening limited to 90°. The factory door opening angle is 115°, and a 90° door opening limiter (stable peg) is supplied for optional use.
All Monolith appliances can be installed individually, Side-by-Side in a single fitted unit or Side-by-Side in separate units. If the distance between two integrated units is less than 102 mm, a Side-by-Side set with sidewall heater and brackets is required. For back-to-back door positioning, a minimum spacing of 154 mm is necessary to avoid handle collisions when opening to the centre with the 90° limiter.
Ventilation requirements
The appliance relies on ventilation through the plinth panel. The grills in the plinth must not be covered. Spacers supplied with the appliance must be fitted to separate warm outgoing air from incoming fresh air. Stainless steel plinth panels are available in widths from 45.7 cm to 182.8 cm, including a 76.2 cm version suited to the EGN 9471.
Water connection and IceMaker use
The IceMaker requires a fixed 3/4' water connection. Water connection work must not be performed while the appliance is connected to the electrical socket. A shut-off valve must be installed between the hose and mains water supply and must not be located behind the appliance. The connection must only be undertaken by a trained and licensed plumber, and water quality must comply with local drinking water regulations.
Monolith appliances with IceMaker must have a water pressure between 2.8 and 6.2 bar. Only the supply hose provided with the appliance may be used. A water softener is recommended in areas with high water hardness, and a filter must be used if solids such as sand are present. The IceMaker is intended solely for producing ice cubes in normal household quantities.
Electrical and safety information
The appliance must be operated on alternating current at the permitted voltage and frequency for the country. Power sockets must be earthed, electrically protected, easily accessible and must not be located directly behind the appliance. A separate circuit is recommended to prevent defrosting caused by other appliances. The unit must not be connected via extension cables, multi-sockets or inverters due to fire and overheating risks.
The refrigerant circuit has been checked for tightness and the appliance meets applicable safety regulations. To prevent tipping, the anti-tipping device supplied must be secured to the floor or wall during installation. After positioning, the appliance should stand in the installation location for one hour before switching on so that coolant and lubrication fluids distribute evenly.
Ambient conditions
The appliance is intended for refrigerating, freezing and storing food and for making ice. Its climate class SN–T allows operation in ambient temperatures from 10°C to 43°C. It must not be operated outside these temperature ranges. The appliance should be installed only next to Liebherr refrigerators, freezers or wine cabinets designed for Side-by-Side installation to avoid condensation and potential damage.
Optional accessories
- Flat brushed aluminium handles (including 810 mm universal and 658 mm freezer-compartment versions).
- Square brushed aluminium handles (810 mm universal and 658 mm freezer-compartment versions).
- Round stainless steel handles (810 mm universal and 658 mm freezer-compartment versions).
- Stainless steel door panels and panel sets sized for Monolith models including 76.2 cm panels suitable for EGN 9471.
- Stainless steel plinth panel 76.2 cm wide, 102 mm high (code 9901 530) for EGN 9471 and matching models.
- Side-by-Side set with sidewall heater, metal brackets, screws and decorative trim.
- Sidewall heater for Side-by-Side installations in separate carcasses where spacing is less than 102 mm.
- Door hinge exchange set (reversal performed by Liebherr authorised engineer).
- Water filter (code 9880 980) for models including EGN 9471.
- Ice accessories such as ice cube scoop and ice cube tongs for compatible models including EGN 9471.
- Cleaning and care products: stainless steel care product 250 ml and stainless steel cleaner 250 ml for all Monolith models.