| Specification | Value |
|---|
| Product name | DA 2360 Extractor unit |
| Material number | 10568370 |
| EAN number | 4002515792193 |
| Old material number | 28236055GB |
| Construction type | Integrated extractor |
| Colour | Stainless steel |
| Energy efficiency class (A+++ – D) | A |
| Annual energy consumption | 49.1 kWh/year |
| AC motor | Yes (AC motor) |
| Fluid dynamic efficiency class | A |
| Lighting efficiency class | A |
| Grease filtering efficiency class | B |
| Canopy width | 584 mm |
| Canopy height | 63 mm |
| Canopy depth | 297 mm |
| Net weight | 11.0 kg |
| Length of supply lead | 1.5 m |
| Standard plug fitted | Yes |
| Controls | Electronic controls; light-touch switches with LEDs |
| Power levels (without Booster) | 3 |
| Booster levels | 1 |
| Lighting | 2 × 3 W LED |
| Light intensity | 350 lx |
| Colour temperature | 3000 Kelvin |
| Filter system | 1 dishwasher-safe 10-ply stainless-steel grease filter |
| Easy-to-clean canopy interior | CleanCover |
| Dual-action blower | Yes |
| Air throughput Level 1 (exhaust) | 250 m³/h (EN 61591) |
| Air throughput Level 2 (exhaust) | 300 m³/h (EN 61591) |
| Air throughput Level 3 (exhaust) | 360 m³/h (EN 61591) |
| Air throughput Booster (exhaust) | 600 m³/h (EN 61591) |
| Sound power Level 1 (exhaust) | 47.0 dB(A) re 1 pW (EN 60704-3) |
| Sound power Level 2 (exhaust) | 48.0 dB(A) re 1 pW (EN 60704-3) |
| Sound power Level 3 (exhaust) | 52.0 dB(A) re 1 pW (EN 60704-3) |
| Sound power Booster (exhaust) | 64.0 dB(A) re 1 pW (EN 60704-3) |
| Sound pressure Level 1 (exhaust) | 31.0 dB(A) re 20 µPa (EN 60704-2-13) |
| Sound pressure Level 2 (exhaust) | 34.0 dB(A) re 20 µPa (EN 60704-2-13) |
| Sound pressure Level 3 (exhaust) | 38.0 dB(A) re 20 µPa (EN 60704-2-13) |
| Sound pressure Booster (exhaust) | 50.0 dB(A) re 20 µPa (EN 60704-2-13) |
| Air throughput Level 1 (recirculation) | 190 m³/h (EN 61591) |
| Air throughput Level 2 (recirculation) | 250 m³/h (EN 61591) |
| Air throughput Level 3 (recirculation) | 320 m³/h (EN 61591) |
| Air throughput Booster (recirculation) | 500 m³/h (EN 61591) |
| Sound power Level 1 (recirculation) | 54.0 dB(A) re 1 pW (EN 60704-3) |
| Sound power Level 2 (recirculation) | 60.0 dB(A) re 1 pW (EN 60704-3) |
| Sound power Level 3 (recirculation) | 64.0 dB(A) re 1 pW (EN 60704-3) |
| Sound power Booster (recirculation) | 72.0 dB(A) re 1 pW (EN 60704-3) |
| Sound pressure Level 1 (recirculation) | 39.0 dB(A) re 20 µPa (EN 60704-2-13) |
| Sound pressure Level 2 (recirculation) | 45.0 dB(A) re 20 µPa (EN 60704-2-13) |
| Sound pressure Level 3 (recirculation) | 49.0 dB(A) re 20 µPa (EN 60704-2-13) |
| Sound pressure Booster (recirculation) | 57.0 dB(A) re 20 µPa (EN 60704-2-13) |
| Minimum height above electric hobs | 450 mm |
| Minimum distance above gas hobs (max. 12.6 kW total, burner ≤ 4.5 kW) | 650 mm |
| Extraction ducting connection | At top and at rear |
| Diameter of exhaust duct | 150 mm |
| Number of phases | 1 |
| Total rated load | 0.22 kW |
| Voltage | 230 V |
| Fuse rating | 10 A |
| Frequency | 50 Hz |
| Safety switch-off | Yes |
| Accessories included | Non-return flap |
| Recirculation conversion kit (order separately) | DUU 151 |
| Active charcoal filter (order separately) | DKF 19-P |