| Specification | Value |
|---|
| Product name | PUR 98 W wall mounted cooker hood |
| Material number | 10434520 |
| EAN number | 4002515752791 |
| Old material number | 28419854GB |
| Construction type | Wall mounted cooker hood |
| Operating modes | Suitable for extraction or recirculation |
| Type of air guide | Can be retrofitted |
| Recirculation conversion kit | DUW 20 (order separately) |
| Active charcoal filter (separate) | DKF 12-P |
| Optional active charcoal filter | DKF 12-R (can be reactivated) |
| Colour | Stainless steel |
| Possible in RAL colour | Yes (specify colour code when ordering) |
| Controls | Electronic controls; Light-touch switches with LEDs |
| Fan power levels (without Booster) | 3 |
| Booster levels | 1 |
| Energy efficiency class (A+++ – D) | A |
| Annual energy consumption | 49.7 kWh/year |
| Motor type | AC motor |
| Fluid dynamic efficiency class | A |
| Lighting efficiency class | A |
| Grease filtering efficiency class | A |
| Canopy interior | Easy-to-clean canopy interior – CleanCover |
| Grease filters | 3 dishwasher-safe stainless steel grease filters (10-ply) |
| Lighting | 3 × 3 W LED |
| Light intensity | 450 lx |
| Colour temperature | 3000 Kelvin |
| Blower | Dual-action blower |
| Air throughput Level 1 (extraction) | 265 m³/h (according to EN 61591) |
| Air throughput Level 2 (extraction) | 320 m³/h (according to EN 61591) |
| Air throughput Level 3 (extraction) | 395 m³/h (according to EN 61591) |
| Air throughput Booster level 1 (extraction) | 650 m³/h (according to EN 61591) |
| Sound power Level 1 (extraction) | 47.0 dB(A) re 1 pW (EN 60704-3) |
| Sound power Level 2 (extraction) | 52.0 dB(A) re 1 pW (EN 60704-3) |
| Sound power Level 3 (extraction) | 56.0 dB(A) re 1 pW (EN 60704-3) |
| Sound power Booster level 1 (extraction) | 67.0 dB(A) re 1 pW (EN 60704-3) |
| Sound pressure Level 1 (extraction) | 32.0 dB(A) re 20 µPa (EN 60704-2-13) |
| Sound pressure Level 2 (extraction) | 37.0 dB(A) re 20 µPa (EN 60704-2-13) |
| Sound pressure Level 3 (extraction) | 41.0 dB(A) re 20 µPa (EN 60704-2-13) |
| Sound pressure Booster level 1 (extraction) | 52.0 dB(A) re 20 µPa (EN 60704-2-13) |
| Air throughput Level 1 (recirculation) | 190 m³/h (according to EN 61591) |
| Air throughput Level 2 (recirculation) | 270 m³/h (according to EN 61591) |
| Air throughput Level 3 (recirculation) | 330 m³/h (according to EN 61591) |
| Air throughput Booster level 1 (recirculation) | 460 m³/h (according to EN 61591) |
| Sound power Level 1 (recirculation) | 54.0 dB(A) re 1 pW (EN 60704-3) |
| Sound power Level 2 (recirculation) | 60.0 dB(A) re 1 pW (EN 60704-3) |
| Sound power Level 3 (recirculation) | 64.0 dB(A) re 1 pW (EN 60704-3) |
| Sound power Booster level 1 (recirculation) | 71.0 dB(A) re 1 pW (EN 60704-3) |
| Sound pressure Level 1 (recirculation) | 39.0 dB(A) re 20 µPa (EN 60704-2-13) |
| Sound pressure Level 2 (recirculation) | 45.0 dB(A) re 20 µPa (EN 60704-2-13) |
| Sound pressure Level 3 (recirculation) | 48.0 dB(A) re 20 µPa (EN 60704-2-13) |
| Sound pressure Booster level 1 (recirculation) | 56.0 dB(A) re 20 µPa (EN 60704-2-13) |
| Safety switch-off | Yes |
| Canopy width | 898 mm |
| Canopy height | 62 mm |
| Canopy depth | 500 mm |
| Overall height – extraction/vented (min) | 685 mm |
| Overall height – extraction/vented (max) | 1005 mm |
| Overall height – recirculation (min) | 815 mm |
| Overall height – recirculation (max) | 1135 mm |
| Net weight | 25.0 kg |
| Length of supply lead | 1.5 m |
| Standard plug fitted | Yes |
| Number of phases | 1 |
| Total rated load | 0.22 kW |
| Voltage | 230 V |
| Fuse rating | 10 A |
| Frequency | 50 Hz |
| Extraction ducting connection at top | Yes |
| Extraction ducting connection at rear | Yes |
| Diameter of exhaust duct | 150 mm |
| Telescopic chimney | Yes |
| Minimum height above electric hobs | 450 mm |
| Minimum safety distance above gas hobs | 650 mm (max. 12.6 kW total power, burner ≤ 4.5 kW) |
| Accessories included | Non-return flap |